1.6Model List
Industrial Ethernet I/O Module Model List
Model Description DC output DC input Power consumption
M100T 1RJ45, 1RS485, 2DI, 2AI, 2DO 1 DC 9~36VDC 160mA@12V
M110T 1RJ45, 1RS485, 4DI, 4DO 1 DC 9~36VDC 160mA@12V
M120T 1RJ45, 1RS485, 4DI, 4AI, 4DO, 2AO 1 DC 24~36VDC 90mA@24V
M130T 1RJ45, 1RS485, 8DI, 4DO 1 DC 9~36VDC 150mA@12V
M140T 1RJ45, 1RS485, 8DI, 8DO 1 DC 9~36VDC 150mA@12V
M150T 1RJ45, 1RS485, 8DI, 4AI, 4DO 1 DC 9~36VDC 150mA@12V
M160T 1RJ45, 1RS485, 8DI, 8AI, 8DO 1 DC 9~36VDC 150mA@12V
M170T 1RJ45, 1RS485, 8DI, 4AI (16bit), 4DO 1 DC 9~36VDC 80mA@12V
M180T 1RJ45, 1RS485, 8DI, 8AI (16bit), 8DO 1 DC 9~36VDC 150mA@12V
M200T 1RJ45, 1RS485, 2AO 1 DC 24~36VDC 90mA@24V
M210T 1RJ45, 1RS485, 4DI 1 DC 9~36VDC 160mA@12V
M220T 1RJ45, 1RS485, 4DO 1 DC 9~36VDC 160mA@12V
M230T 1RJ45, 1RS485, 4AI 1 DC 9~36VDC 160mA@12V
M240T 1RJ45, 1RS485, 4 RTD,
2/3wire PT100/PT1000 1 DC 9~36VDC 100mA@12V
M310T 1RJ45, 1RS485, 8DI 1 DC 9~36VDC 150mA@12V
M320T 1RJ45, 1RS485, 8DO 1 DC 9~36VDC 150mA@12V
M330T 1RJ45, 1RS485, 8AI 1 DC 9~36VDC 150mA@12V
M340T 1RJ45, 1RS485, 8 RTD
2/3 wire PT100/PT1000 1 DC 9~36VDC 100mA@12V
M350T 1RJ45, 1RS485, 8TC,
B/E/J/K/N/R/S/T 1 DC 9~36VDC 80mA@12V
M360T 1RJ45, 1RS485, 8AI (16bit) 1 DC 9~36VDC 150mA@12V
M410T 1RJ45, 1RS485, 16DI 1 DC 9~36VDC 160mA@12V
M420T 1RJ45, 1RS485, 16DO 1 DC 9~36VDC 110mA@12V
2.1Overview
The M series Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1 Industrial 10/100M adaptive Ethernet module inside. It comes with multi I/O, supports standard Modbus TCP, supports Modbus master and slave, can be integrated into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.
The M series Ethernet Remote I/O module comes with a RS485 interface, through the RS485 bus, it can cascade Modbus I/O devices or Modbus meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus I/O data are automatically collected to the register mapping area, the TCP Client polling without waiting then can get a quick response to meet the industrial timely requirements.
The M series Ethernet Remote I/O module features different I/O ports for variety applications. Includes optical-isolated digital inputs, compatibles dry contact and wet contact, supports max 700KHz high speed pulse counter; digital outputs supports 10Hz~300Khz high speed pulse output or relay outputs; isolated 12bit and 16bit analog inputs, support 0~5V, 0~10V, 4~20mA, 0~20mA analog signal; 12bits analog outputs, supports 0~10VDC signal output; resistance thermal detector inputs compatible 2/3 wires PT100 and PT1000, and thermocouple inputs. All the I/O interfaces are high sampling frequency and special filtering strategy to ensure its reliability.
The M series Ethernet Remote I/O module can work at wide working voltage range, the range is 12 ~ 36VDC with anti-reverse protection design. Also, it provides 1channel 12~36VDC power output for external device to save wiring cost.
|
|